Zero Surge manufactures the first surge
suppressors to be certified to the highest U.S. government classification:
 | Grade A Endurance |
 | Class 1 Performance |
 | Mode 1 Applications |
 | Surge suppressors that safeguard against damage and disruption
to delicate electronic equipment. |
 | Zero Surge products do not contain MOVs.
|
WHEN YOU CONSIDER A SURGE SUPPRESSOR, ASK YOURSELF:
WILL MY SURGE SUPPRESSOR WORK?
When you purchase a new product, you normally check to see how well it works.
How will you check a new surge suppressor?
SEE THE PROBLEM?
Suppressor manufacturers can make outrageous claims that you cannot
verify.
To assure our clients they are receiving protection that actually works, and is also
the best protection available for their important applications, Zero Surge has submitted
our product technology to a Nationally Recognized Testing Laboratory for performance
verification to new US government commercial performance standards.
Our technology has been verified as passing the highest classification: Grade A
Endurance, Class 1 Performance, Mode 1 Applications.
Refer to "Features and Benefits"
section of our web site for the full details of this new US government testing standard.
Before you buy another suppressor, and if your application is important, ask the
manufacturer for the test results to this new commercial performance standard! Are
they offering you a Grade A product, or an inferior product?
Product Specifications
The product specifications listed in the table below are for all models in the
Standard Line. The same core technology is used throughout the entire Zero Surge product
line. Information describing the product grouping is shown adjacent to each photograph.
Please call 905-415-8655 \ 888-509-2177 for pricing information.
New Commercial
Performance Specification: |
Grade A Endurance, Class 1 Performance, Mode 1
Applications - 1,000 surges, 3,000 amperes, SVR = 330, actual Suppressed Voltage
= 280 Volts, no failures, L-N (ground wire protection) mode. |
| UL 1449 Listed*: |
UL 1449 SVR: 330 volts (peak let-through voltage @
3,000 amps) |
| UL 1449 Adjunct Classification Test Results
(initial submission)*: |
1,000 surges, 6,000 v, 3,000 amp, C1 pulse, measured
Suppressed Voltage, 280 v, no failures. 3,000 amp SVR: 330 v. |
| Limiters: |
Series surge reactor current limiter;
cascaded, auto-tracking dual polarity voltage limiter; dual cascaded pulse
inverters. |
| Clamping Voltage Onset:
|
172 volts nominal; 2 volts above peak line voltage
(auto-tracking). |
| Filter: |
(bi-directional, wave tracking): With 50 ohm Rg load:
3 dB @ 3kHz; 38 dB @ 100 kHz; 50 dB @ 300 kHz. |
| Let Through Slew Rate: |
5,000 v/microsec. disturbance reduced to 28 v/microsec.
within AC power wave envelope, and less than 10 v/microsec. outside the
power wave envelope. |
| Snubbers: |
Instant acting snubbers for very fast-rising surges
generated within the building |
| Joule Rating Limitation
|
Unlimited rating (due to current limiting) (8 X 20
microsec.) |
| Maximum Surge Pulse Voltage:
|
6,000 volts (1.2 X 50 microsec.) (Industry Standard
rating) |
| Maximum Surge Pulse Current Rating:
|
>100,000 amperes (unlimited due to current limiting)
(8 X 20 microsec.) |
| Service Life, C62.41-1991 (formerly IEEE 587)
Category B3 (C1) pulses: |
2 kv >100,000; 4 kv > 10,000; 6 kv > 1,000 (NRTL-UL
certified) |
* Applies to Standard Line Models
Stand Alone Products
8R Series
 |
8R7.5W
7.5 amp desktop unit. The switch enables the product to be used as a master
On/Off switch. Will handle 1 or 2 typical computer systems. 8 outlets, 6
switched, 2 always on.
8.25”L x
4”W x 4”H, 5.75 lb.
Data Sheet |
8R15W
15 amp desktop unit. Like the 8R7.5, it can be used as a master On/Off
switch, but will handle 2 to 3 typical computer systems. 8 outlets, 6
switched, 2 always on.
8.25”L x 4”W x 4”H, 5.75 lb.Data
Sheet |
8R7.5W-TWR Tower Model
Same as the 8R7.5 but stands vertically to save space.
4”L x 4”W
x 8.25”H, 5.75 lb.
Data Sheet |
8R15W-TWR Tower Model
Same as the 8R15 but stands vertically to save space.
4”L x 4”W
x 8.25”H, 5.75 lb.
Data Sheet |
2R Series
 |
2R7.5W
7.5 amp unit, for preceding a UPS or a power strip. Will protect 1 or 2
typical computer systems.
8”L x 4”W
x 3”H, 5.5 lb. Data
Sheet |
2R15W
15 amp unit, for preceding a UPS or a power strip. Will protect 2 or 3
typical computer systems.
|
2R15W-GDR
20 amp reactor, 15 amp power cord, and 15 amp hospital grade receptacles.
|
2R20W-GDR
20 amp reactor, 20 amp power cord, and 20 amp hospital grade receptacles.
8”L x 4”W
x 3”H, 5.5 lb.Data Sheet |
|